苏州宝威汽车部件待遇:帮忙翻译,谢谢!!!加分!!!急啊!!!!
来源:百度文库 编辑:神马品牌网 时间:2024/10/06 10:04:13
I graduated from the electrical company was assigned to the Jilin Jinuoer, after-sale services sector to date. I work mainly refrigerators, ice-blocks maintenance, installation and maintenance of air conditioners. Cases : refrigerators (Jinuoer 208), electric, compressor start functioning normally, but not refrigeration, cold storage room to hear a capillary gas voices judged as a refrigerant, since 208 for Lu:guan internal organs, the initial judgment of the evaporator leaking, compressor cutting low voltage lines, to the evaporator pressure, pressure gauge hit 10 postponed screw tight, two hours after the pressure dropped to seven pressure on the vaporizer is leaking Department, refrigerators buildings disconnected, open heat preservation layer down evaporator, into the brass evaporator, the evaporator condensers and at the same time suppressing leakage, without disclosing, a heat preservation layer, the huge pressure well, pumping vacuum plus fluorine, normal functioning, refrigeration. AC (cymbidium 1P wall hanging type air-conditioning sub-groups), indoor plant switch on the machine, only the wind out, not refrigeration, indoor temperature higher than a temperature check, the fans running, but not activated compressors, power will be the case opened, with external table inspection compressors and compressor start capacitance, and finally start capacitance measurement capacity, for the same capacity condenser after ban plane. Compressors activated indoor mechanism cold normal. Haier 1.5P wall hanging air-conditioning, refrigeration, poor switch on the machine to check the plane, a grease valves, wall charts 1,117,000, plus fluorine, refrigeration normal, there will be grease outside of the valves screw tight, with no evidence of the bubble leaking water home after repairs
好,来了
After myself graduate am assigned to the Jilin lucky lake electric appliance group company, post-sale service department work until now. My work mainly includes the refrigerator, the refrigerator service, the air-conditioner installment and the service. Example: After the refrigerator (lucky lake 208) the circular telegram, the compressor starts the revolution to be normal, but does not refrigerate, the cold-storageroom internal energy hears the capillary vessel the sound which was mad, judges for does not have the refrigerant, because 208 interior are the aluminum tube organizations, the preliminary judgment for under evaporator revelation, after compressor low pressure pipeline cutting, hits to the evaporator the pressure, after the pressure gauge projects on 10 pressures to screw tight, after 2 hours the drop of pressure to 7 pressures, showed the evaporator has the revelation place, disassembles the refrigerator back board, opens the heat insulating layer, takes down the evaporator, after exchanges the copper pipe the evaporator, simultaneously hits for the evaporator and the condenser presses the leak detection, after does not have the revelation, completes the heat insulating layer, the back boardAfter presses, pulls out the vacuum to add the fluorine, the revolution is normal, refrigeration. Air conditioning (cymbidium virens 1P wall hanging type fission air conditioning), after in room refrigerator starting, only then the wind blows out, does not refrigerate, because the indoor temperature is higher than the establishment temperature outside, examines machine the ventilator revolution, but the compressor does not start, after the power failure machine the outer covering will open, will start the electric capacity with the external use table inspection compressor and the compressor, finally will determine the start electric capacity capacity, after will trade the same level capacity the capacitor the testing. The compressor starts, in the room machine the refrigeration is normal. Haire the 1.5P wall hanging type air conditioning, after starting refrigerates the difference, outside examined machine outside the valve has the greasy dirt, after hangs the table to measure presses, after adds the fluorine, the refrigeration is normal, will have outside the greasy dirt outside machine valve to screw tight, after froth Shui Jiacha proved will not have the revelation, the service finished.